BESS Armhoede

In April 2023, Minister Jetten announced, as part of his Climate Package, that the installation of a battery at solar parks would become mandatory. TPSolar therefore integrates a battery energy storage system (hereinafter BESS) into all its designs for new solar parks.

What is a BESS?

There is a growing need for large-scale electricity storage in the Netherlands. This is achieved using specialised battery systems, which are essentially very large versions of the batteries found in electric bikes or electric cars. These store electricity when it is not needed and can then supply it at times when it is required. In this way, these large batteries help to restore the balance between supply and demand for (green) energy. We, too, are set to deploy these battery systems and have asked Liander about the possibilities for installing such a system on the site of the Armhoede Solar Park.

​Large-scale energy storage at Armhoede Solar Park

Liander has calculated that it is possible to implement a BESS on the site of Armhoede Solar Park and has granted permission for a battery system with a capacity of up to 10 MVA. ​The proposed location for the batteries is in the far north-western corner of the former recycling centre, at a more than sufficient distance from the high-voltage power lines and the surrounding homes.

This battery system consists of eight battery containers and two transformer/inverter units. A well will be drilled at the planned site to provide a fire-fighting water supply. The installation will be connected to the solar park’s existing cable. The image below shows a visualisation of the battery system’s layout.

Safety

Safety is a key aspect of the licensing procedure. There have been significant improvements in this area in recent years. The risk of a fire or explosion is therefore minimal with modern systems. Should a fire nevertheless break out, the systems are designed to contain the fire or explosion within the containers and to extinguish it automatically. The likelihood of such an incident causing damage in the immediate vicinity of the container in question is virtually nil. To rule out all risks, a 4-metre buffer zone is maintained around the installation.

​Radiation and noise

The battery system operates largely on direct current (DC), which does not emit any electromagnetic radiation. However, electromagnetic radiation is emitted by the two transformer/inverter stations. These transformer stations are similar to those used in the solar park, and the radiation is negligible at a distance of more than 4 metres. The noise level of the battery installation is also comparable to that of a transformer/inverter installation at the solar park. The battery installation will be situated at roughly the same distance from the homes as the transformer/inverter installations at the solar park.

Contact

Do you have a question about EOS Armhoede in Lochem? Please contact us at info@tpsolar.nl or on 023 741 01 44